| Operational modes: | 
							Direct bus connection to ECoSlink. Operation with ECoS or Central Station Reloaded V3.0.0. is possible. | 
					
					
							| Feedback section: | 
							16 feedback modules. | 
					
					
							|   | 
							Configurable by using jumpers as digital inputs (e.g. for contact tracks or reed switches) or as track occupancy detectors (current sensor). | 
					
					
							|   | 
							Galvanical isolation of feedback modules and command station | 
					
					
							|   | 
							Max. 3A current load per feedback input | 
					
					
							| RailCom®: | 
							4 of 16 feedback sections can be used as RailCom feedback sections ("local detector"), if desired. Recognition of loco address | 
					
					
							| Dimensions: | 
							86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) | 
					
					
							| Included in delivery: | 
							ECoSDetector feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual | 
					
					
							|   | 
							  | 
					
					
							|   | 
							ECoSDetector Standard | 
					
					
							| Operational modes:  | 
							Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible. | 
					
					
							| Feedback section:  | 
							16 feedback modules as digital inputs (e.g. for contact tracks or reed switches). Galvanical isolation of feedback modules and command station. | 
					
					
							| Dimensions:  | 
							86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) | 
					
					
							| Included in delivery:  | 
							ECoSDetector Standard feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual | 
					
					
							|   | 
							  | 
					
					
							|   | 
							ECoSDetector RC | 
					
					
							| Operational modes:  | 
							Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible. | 
					
					
							| Feedback section:  | 
							4 feedback inputs configured as track occupancy detectors (current sensor). Galvanical isolation of feedback modules and command station. | 
					
					
							| RailCom®: | 
							4 feedback sections can be used as RailCom feedback sections ("local detector"). Recognition of loco address | 
					
					
							| Dimensions:  | 
							86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) | 
					
					
							| Included in delivery:  | 
							ECoSDetector RC feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual | 
					
					
							|   | 
							  | 
					
					
							|   | 
							ECoSDetector Extension | 
					
					
							| Operational modes: | 
							Extension module for ECoSDector, is powered and controlled by it. Transistor outputs are powered externally. | 
					
					
							| Outputs: | 
							32 transistor outputs, 100mA output load each. Construction as „open collector“ is connected to ground | 
					
					
							|   | 
							Total current of all outputs is max. 1.5A | 
					
					
							| Dimensions: | 
							86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) | 
					
					
							| Included in delivery: | 
							ECoSDetector Extension module, terminals, extensive instruction manual |